Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520228

ABSTRACT

ABSTRACT Purpose: The emergency medical service is a fundamental part of healthcare, albeit crowded emergency rooms lead to delayed and low-quality assistance in actual urgent cases. Machine-learning algorithms can provide a smart and effective estimation of emergency patients' volume, which was previously restricted to artificial intelligence (AI) experts in coding and computer science but is now feasible by anyone without any coding experience through auto machine learning. This study aimed to create a machine-learning model designed by an ophthalmologist without any coding experience using AutoML to predict the influx in the emergency department and trauma cases. Methods: A dataset of 356,611 visits at Hospital da Universidade Federal de São Paulo from January 01, 2014 to December 31, 2019 was included in the model training, which included visits/day and the international classification disease code. The training and prediction were made with the Amazon Forecast by 2 ophthalmologists with no prior coding experience. Results: The forecast period predicted a mean emergency patient volume of 216.27/day in p90, 180.75/day in p50, and 140.35/day in p10, and a mean of 7.42 trauma cases/ day in p90, 3.99/day in p50, and 0.56/day in p10. In January of 2020, there were a total of 6,604 patient visits and a mean of 206.37 patients/day, which is 13.5% less than the p50 prediction. This period involved a total of 199 trauma cases and a mean of 6.21 cases/day, which is 55.77% more traumas than that by the p50 prediction. Conclusions: The development of models was previously restricted to data scientists' experts in coding and computer science, but transfer learning autoML has enabled AI development by any person with no code experience mandatory. This study model showed a close value to the actual 2020 January visits, and the only factors that may have influenced the results between the two approaches are holidays and dataset size. This is the first study to apply AutoML in hospital visits forecast, showing a close prediction of the actual hospital influx.


RESUMO Objetivo: Esse estudo tem como objetivo criar um modelo de Machine Learning por um oftalmologista sem experiência em programação utilizando auto Machine Learning predizendo influxo de pacientes em serviço de emergência e casos de trauma. Métodos: Um dataset de 366,610 visitas em Hospital Universitário da Universidade Federal de São Paulo de 01 de janeiro de 2014 até 31 de dezembro de 2019 foi incluído no treinamento do modelo, incluindo visitas/dia e código internacional de doenças. O treinamento e predição foram realizados com o Amazon Forecast por dois oftalmologistas sem experiência com programação. Resultados: O período de previsão estimou um volume de 206,37 pacientes/dia em p90, 180,75 em p50, 140,35 em p10 e média de 7,42 casos de trauma/dia em p90, 3,99 em p50 e 0,56 em p10. Janeiro de 2020 teve um total de 6.604 pacientes e média de 206,37 pacientes/dia, 13,5% menos do que a predição em p50. O período teve um total de 199 casos de trauma e média de 6,21 casos/dia, 55,77% mais casos do que a predição em p50. Conclusão: O desenvolvimento de modelos era restrito a cientistas de dados com experiencia em programação, porém a transferência de ensino com a tecnologia de auto Machine Learning permite o desenvolvimento de algoritmos por qualquer pessoa sem experiencia em programação. Esse estudo mostra um modelo com valores preditos próximos ao que ocorreram em janeiro de 2020. Fatores que podem ter influenciados no resultado foram feriados e tamanho do banco de dados. Esse é o primeiro estudo que aplicada auto Machine Learning em predição de visitas hospitalares com resultados próximos aos que ocorreram.

3.
Arq. bras. oftalmol ; 86(5): e20230067, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513676

ABSTRACT

ABSTRACT Purpose: This study aimed to describe the visits profile to Hospital São Paulo's ophthalmology emergency department, a 24-hour public open-access tertiary-care service in São Paulo, Brazil, that belongs to Federal University of São Paulo, over the last 11 years. Methods: A cross-sectional retrospective study was conducted, including all patients (n=634,726) admitted to the ophthalmology emergency department of Hospital São Paulo between January 2009 and December 2019. Results: From 2009 to 2019, the number of patients' presentations increased to 39.2%, with considerable visits variation across the period. The median age was 38 ± 20.4 years. Males represented 53.3%, and single-visit patients represented 53.1%. A total of 79.5% of patients' presentations occurred from 7 am to 5 pm, and 80.8% of patients' presentations occurred during regular weekdays. The most frequent diagnoses were conjunctivitis, blepharitis, keratitis, hordeolum/chalazion, and corneal foreign body. Conclusions: Over the study period, presentations significantly increased in number, with nonurgent visits predominance, and a low number of single-visit patients. Our results demonstrate the ophthalmic visits profile and can lead to changes in the public health system to improve the quality of care and ophthalmology emergency access in São Paulo city.


RESUMO Objetivos: O objetivo do estudo é avaliar o perfil das visitas ao Pronto-Socorro de Oftalmologia (PS) do Hospital São Paulo, serviço público de atendimento terciário aberto 24 horas em São Paulo - Brasil, pertencente à Universidade Federal de São Paulo, nos últimos 11 anos. Métodos: Foi realizado um estudo transversal retrospectivo, com base em todos os pacientes (n=634.726) admitidos no pronto-socorro de oftalmologia do Hospital São Paulo entre janeiro de 2009 e dezembro de 2019. Resultados: De 2009 a 2019, houve um aumento no influxo de 39,2% com importante variação nos atendimentos ao longo dos anos, a mediana de idade foi de 38 ± 20,4 anos, o sexo masculino representou 53,3% e os pacientes únicos representaram 53,1%. Verificou-se que 79,5% das visitas ocorreram das 7h às 17h e 80,8% nos dias da semana. Os diagnósticos mais frequentes foram conjuntivite aguda seguida de blefarite, ceratite, hordéolo / calázio e corpo estranho corneano. Conclusão: Ao longo do período de análise do estudo, houve importante aumento nas apresentações, com predominância de atendimentos não urgentes e baixa proporção de pacientes com uma única visita. Nossos resultados evidenciam o perfil das consultas oftalmológicas, podendo gerar mudanças no sistema público de saúde visando a melhoria da qualidade do atendimento e acesso às emergências oftalmológicas na cidade de São Paulo.

4.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 69(10): e20230848, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1514686

ABSTRACT

SUMMARY OBJECTIVE: The aim of this study was to evaluate the performance of ChatGPT-4.0 in answering the 2022 Brazilian National Examination for Medical Degree Revalidation (Revalida) and as a tool to provide feedback on the quality of the examination. METHODS: A total of two independent physicians entered all examination questions into ChatGPT-4.0. After comparing the outputs with the test solutions, they classified the large language model answers as adequate, inadequate, or indeterminate. In cases of disagreement, they adjudicated and achieved a consensus decision on the ChatGPT accuracy. The performance across medical themes and nullified questions was compared using chi-square statistical analysis. RESULTS: In the Revalida examination, ChatGPT-4.0 answered 71 (87.7%) questions correctly and 10 (12.3%) incorrectly. There was no statistically significant difference in the proportions of correct answers among different medical themes (p=0.4886). The artificial intelligence model had a lower accuracy of 71.4% in nullified questions, with no statistical difference (p=0.241) between non-nullified and nullified groups. CONCLUSION: ChatGPT-4.0 showed satisfactory performance for the 2022 Brazilian National Examination for Medical Degree Revalidation. The large language model exhibited worse performance on subjective questions and public healthcare themes. The results of this study suggested that the overall quality of the Revalida examination questions is satisfactory and corroborates the nullified questions.

5.
Arq. bras. oftalmol ; 86(6): e2021, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520208

ABSTRACT

ABSTRACT Purpose: The COVID-19 pandemic began in March 2020 and changed the healthcare system overall. The pandemic led to resource allocation changes, overloading of intensive care units, apprehensiveness of patients to seek medical care not related to COVID-19, and an abrupt reduction in all nonurgent consultations and surgeries. This study evaluated the impact on an ophthalmological emergency room for one year by assessing the correlation between societal lockdown phases and COVID-19 mortality. Methods: An observational, retrospective study was conducted that included all patients admitted to the Ophthalmology Emergency Department between January 1, 2019, and March 28, 2021. The visits were classified into prepandemic and pandemic groups that were then compared. Results: In the prepandemic period, the hospital registered a total of 71,485 visits with a mean of 194.78 ± 49.74 daily visits. In the pandemic group, there was a total of 41,791 visits with a mean of 114.18 ± 43.12 daily visits, which was a 41.4% decrease. A significant decrea­se (16.4 p<0.001) was observed in the prevalence of acute conjunctivitis, and a significant increase (6.4%; p<0.01) was observed in the prevalence of corneal foreign body disorders. A negative correlation was identified between the COVID-19 death rate and the ophthalmological inflow rates. Conclusion: This one-year analysis showed a reduction of 41.4% in emergency department visits and a significant decrease in infectious conditions. A change in hygiene habits and social distancing could explain this reduction, and the increased prevalence of trauma consultations highlighted the need for preventive and educative measures during these types of restrictive periods.


RESUMO Objetivos: A pandemia de COVID-19 foi iniciada em março de 2020 e mudou o sistema de saúde. Mudanças na alocação de recursos, sobrecarga de unidades de terapia intensiva, apreensão dos pacientes em procurar atendimento médico não relacionado ao COVID-19 e redução abrupta de todas as consultas e cirurgias não urgentes. Este estudo avalia o impacto em um pronto-socorro oftalmológico após 1 ano de pandemia, avaliando a correlação entre as fases de lockdown, a mortalidade do COVID-19 e as visitas ao pronto-socorro. Métodos: Estudo observacional retrospectivo que incluiu todos os pacientes admitidos no serviço de emergência oftalmológica do Hospital São Paulo, vinculado a UNIFESP/EPM, entre 1º de janeiro de 2019 e 28 de março de 2021. As visitas foram classificadas e comparadas em um grupo pré-pandemia e pandemia. Resultados: No período pré-pandemia, o hospital registrou um total de 71.485 atendimentos com média de 194,78 ± 49,74 atendimentos diários, e no grupo pandemia, um total de 41.791 com média de 114,18 ± 43,12 atendimentos diários, redução de 41,4%. Uma diminuição significativa de 16,4% (p<0,001) foi observada na prevalência de conjuntivite aguda e um aumento significativo de 6,4% (p<0,01) na prevalência de corpo estranho da córnea. Foi identificada uma correlação negativa entre a taxa de mortalidade do COVID-19 e as taxas de visita ao pronto-socorro. Conclusão: Esta análise de um ano mostrou uma redução de 41,4% nas visitas ao pronto-socorro, e uma diminuição significativa nas conjuntivites agudas. A mudança nos hábitos de higiene e o distanciamento social poderiam explicar essa redução, e o aumento da prevalência de traumas corneanos. Achados destacam a necessidade de medidas preventivas e educativas durante os períodos restritivos.

9.
Rev bras oftalmol ; 79(3): 169-173, May/June 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1137953

ABSTRACT

Abstract Objective: To evaluate the choroidal thickness (CT) in healthy Brazilian subjects using spectral-domain optical coherence tomography (SD-OCT) and to compare with choroidal thickness measured in Brazilian patients with diabetic macular edema (DME), neovascular age-related macular degeneration (AMD) and high myopia. Methods: A retrospective analysis of spectral domain optical coherence tomography (SD-OCT) images of 181 Brazilian subjects. A total of 74 eyes were included in the normal control group, 50 eyes in the nvAMD group, 44 eyes in the DME group and 13 eyes in the high myopia group. CT was measured from the posterior edge of the retinal pigment epithelium (RPE) to the choroid/sclera junction at the fovea and at 500 μm intervals temporal and nasal to the fovea. All measurements were performed by two independent observers and were averaged for analysis. The statistical analysis and comparison were performed using Mann Whitney (unpaired t-test). Results: Seventy-four eyes from 74 patients with a mean age of 51.4 years were analyzed in the normal group with a mean nasal, subfoveal and temporal choroidal thickness measurements were 301.30 ± 12.86 μm, 311.61 ± 12.62 μm and 309.28 ± 12.28 μm respectively. All groups with disease demonstrated a statistically significant choroidal thinning when compared with matched-aged normal eyes. The mean reduction in the nvAMD group compared to normal were 60.65 μm nasally, 59.77 μm temporally and 56.59 μm at subfoveal position. In the DME group, the subfoveal reduction was 51.10 μm, 63.03 μm and 46.30 μm, nasally and temporally. The patients with high myopia presented the greatest reduction in CT compared to normal eyes, with a mean reduction of 159.9 nasal, 159.98 subfoveal and 154.65 at temporal. Conclusions: The present study evaluated choroidal thickness in Brazilian subjects, with intense miscegenation. The results demonstrated a statistically significant decrease of the choroidal thickness in all subtypes of chorioretinal disease. The small sample size in this study was a limitation. Additional research with a larger study population to better understand these findings.


Resumo Objetivo: Avaliar a espessura da coróide (EC) de indivíduos brasileiros saudáveis utilizando tomografia de coerência ótica do domínio espectral (TCO-DE) e compará-la à espessura da coroide de pacientes brasileiros com edema macular diabético (EMD), degeneração macular neovascular relacionada à idade (DMRI) e miopia alta. Metodologia: Análise retrospectiva de imagens de tomografia de coerência ótica de domínio espectral (TOC-DE) de 181 indivíduos brasileiros. Um total de 74 olhos foram incluídos no grupo controle normal; 50, no grupo DMRI; 44, no grupo EMD; e 13, no grupo com miopia alta. A EC foi medida a partir da borda posterior do epitélio pigmentar da retina (EPR) até a junção coróide/esclera na fóvea e de intervalos de 500 μm, temporal e nasal, à fóvea. Todas as medidas foram realizadas por dois observadores independentes e as médias foram calculadas para análise. A análise estatística e a comparação das ECs foram realizadas usando o teste Mann Whitney (teste t não pareado). Resultados: Setenta e quatro olhos de 74 pacientes com idade média de 51,4 anos foram analisados no grupo normal, o qual apresentou espessura coróide nasal, subfoveal e temporal média igual a 301,30 ± 12,86 µm, 311,61 ± 12,62 µm e 309,28 ± 12,28 µm, respectivamente. Todos os grupos com doença demonstraram afinamento de coroide estatisticamente significativo quando comparados a olhos normais pareados por idade. A redução média de EC no grupo DMRI em comparação ao normal foi de 60,65 μm por via nasal, 59,77 μm por via temporal e 56,59 μm na posição subfoveal. O grupo EMD apresentou redução de EC igual a 51,10 μm em posição subfoveal, 63,03 μm por via nasal e 46,30 μm por via temporal. Pacientes com miopia alta apresentaram a maior redução de EC em relação aos olhos normais; os valores de redução média obtidos foram 159,9 por via nasal, 159,98 em posição subfoveal e 154,65 por via temporal. Conclusões: O presente estudo avaliou a espessura da coróide de indivíduos brasileiros com intensa miscigenação. Os resultados demonstraram reducção estatisticamente significativa da espessura da coróide em todos os subtipos de doença coriorretiniana. O pequeno tamanho da amostra foi uma limitação deste estudo. Pesquisas adicionais com população maior de estudo deveriam ser realizadas para ajudar a entender melhor esses achados.

10.
Arq. bras. oftalmol ; 83(1): 76-81, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088947

ABSTRACT

ABSTRACT The point of centration for refractive surgery is a theme of great importance that generates considerable discussion among specialists and surgeons in the field. Notably, any changes in light can alter the size of the pupil, and the visual axis of the fixation line to the fovea is unique in each patient. A variety of options have been described in the literature with respect to centration in refractive surgery, and the results differ among these methods. No consensus has been established regarding the ideal refractive surgery technique for evaluation of centration in each patient that will yield a satisfactory surgical result.


RESUMO O ponto de centralização da cirurgia refrativa é tema de grande importância e gera muita discussão entre especialistas e cirurgiões da área. Afinal, qualquer alteração na luz pode alterar o tamanho da pupila, além disso, o eixo visual da linha de fixação para a fóvea é particular em cada paciente. Existem opções para centralização em cirurgia refrativa com resultados diferentes na literatura. Ainda não há consenso sobre a melhor técnica em cirurgia refrativa que avalie cada caso específico visando um resultado cirúrgico final satisfatório.


Subject(s)
Humans , Pupil/physiology , Cornea/surgery , Keratomileusis, Laser In Situ/methods , Lasers, Excimer , Refraction, Ocular , Cornea/pathology , Fixation, Ocular
13.
Arq. bras. oftalmol ; 80(2): 122-124, Mar.-Apr. 2017. graf
Article in English | LILACS | ID: biblio-838790

ABSTRACT

ABSTRACT Drusen are extracellular deposits between the basal lamina of the retinal pigment epithelium (RPE) and the inner collagenous layer of Bruch's membrane. Large colloid drusen (LCD) are located below the RPE and are characterized by multiple, large, dome-shaped RPE detachments, with marked attenuation of the ellipsoid zone overlaying the drusen. This report presents the structural en face optical coherence tomography (OCT) findings of LCD and relates them to findings from fluorescein and indocyanine green angiography. We describe the case of a 55-year-old woman who presented with the chief complaint of a 5-year history of progressively worsening vision. Her best-corrected visual acuities were 20/40 and 20/400 in the right eye and the left eye, respectively. Fundus examination showed large bilateral, symmetrical, sub-retinal, yellowish lesions compatible with LCD. We describe the structural en face OCT characteristics and angiographic findings from this patient.


RESUMO Drusas são depósitos extracelulares localizados entre a lâmina basal do epitélio pig mentado da retina (RPE) e a camada colágena interna da membrana de Bruch. Drusas grandes coloidais (LCD) estão localizadas abaixo do EPR, e são caracterizadas por múltiplos descolamentos cupuliformes do EPR com atenuação da zona elipsoide sobrejacente às drusas. O objetivo deste relato é apresentar os achados de tomografia de coerência óptica (OCT en face estrutural em uma paciente com LCD, bem como correlacioná-los com angiografia fluoresceínica e angiografia com indocianina verde. Descrevemos o caso de uma paciente do sexo feminino, 55 anos, que referiu baixa acuidade visual em ambos os olhos há 5 anos. Sua acuidade visual corrigida era de 20/40 no olho direito e 20/400 no olho esquerdo. Ao exame fundoscópico a paciente apresentava lesões compatíveis com drusas grandes coloidais. As características tomográficas e angiográficas também são descritas neste relato de caso.


Subject(s)
Humans , Female , Middle Aged , Retinal Drusen/diagnostic imaging , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Coloring Agents , Retinal Pigment Epithelium/diagnostic imaging , Indocyanine Green
14.
Arq. bras. oftalmol ; 79(3): 155-158, graf
Article in English | LILACS | ID: lil-787336

ABSTRACT

ABSTRACT Purpose: To evaluate choroidal thickness (CT) using spectral domain optical coherence tomography (SD-OCT) imaging at baseline and 6 months after intravitreal anti-vascular endothelial growth factor (anti-VEGF) treatment in patients with diabetic macular edema (DME). Methods: A retrospective chart review was performed to identify patients with DME who underwent intravitreal injection of anti-VEGF (bevacizumab or ranibizumab) in a pro re nata (PRN) regimen. Subfoveal choroidal thickness was compared between values obtained at baseline and at 6-month follow-up visits. Results: Thirty-nine eyes (15 females, 24 males) from 39 patients were enrolled (mean age, 62.43 ± 8.7 years; range, 44-79 years). Twenty-three and 16 eyes were treated with ranibizumab and bevacizumab respectively. The mean number of anti-VEGF injections was 2.28 ± 1.27 (range, 1-5). Mean nasal, subfoveal, and temporal choroidal thickness (CT) measurements at baseline were 234.10 ± 8.63 µm, 246.89 ± 8.94 µm, and 238.12 ± 8.20 µm, respectively, and those at 6 months post-treatment were 210.46 ± 8.00 µm, 215.66 ± 8.29 µm, and 212.43 ± 8.14 µm, respectively. Significant differences in CT were observed between baseline and the 6-month follow-up at all measured points (p=0.0327). Conclusions: Over a 6-month period, the use of intravitreal anti-VEGF was associated with significant thinning of the choroid in patients with DME. The clinical significance of a thinner choroid in DME is currently unknown; however, it may contribute to long-term adverse effects on choroidal and retinal function, representing an area requiring future investigation.


RESUMO Objetivos: Avaliar a espessura de coroide pré-tratamento e após 6 meses da injeção intravítrea de anti-fator de crescimento vascular endotelial (anti-VEGF) em pacientes com edema macular diabético (EMD), utilizando a tomografia de coerência óptica de domínio espectral (SD-OCT). Métodos: Análise retrospectiva, com revisão de prontuários, foi realizada para identificação de pacientes submetidos a tratamento com injeções intravítreas de anti-VEGF, no regime pro re nata, para tratamento de EMD. As medidas da espessura de coroide pré-tratamento foi comparada com as medidas após acompanhamento de 6 meses. Resultados: Trinta e nove olhos de 39 pacientes (15 femininos, 24 masculinos) foram incluídos, com idade média de 62,43 ± 8,7 anos (variando de 44-79 anos). Trinta e três olhos foram tratados com ranibizumab e 18 com bevacizumab. O número médio de injeções de anti-VEGF foi 2,28 ± 1,27 (variando de 1-5). A medida média pré-tratamento da espessura de coroide nasal, subfoveal e temporal foi 234,10 ± 8,63 µm, 246,89 ± 8,94 µm e 238,12± 8,20 µm, respectivamente. Após acompanhamento de 6 meses as medidas médias da espessura de coroide foram 210,46 ± 8,00 µm, 215,66 ± 8,29 µm e 212,43 ± 8,14 µm. A diferença entre as medidas médias pré e pós tratamento foi estatisticamente significante (p=0,0327) em todos os pontos medidos. Conclusão: Após um período de 6 meses, o uso de injeções intravítreas de anti-VEGF foi associado com diminuição significante da espessura de coroide nos pacientes com EMD. O significado clínico de uma coroide mais fina nos pacientes com EMD é desconhecido mas pode causar eventos adversos a longo prazo para função da coroide e retina, representando uma área para futura investigações.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Macular Edema/drug therapy , Choroid/drug effects , Choroid/pathology , Diabetic Retinopathy/drug therapy , Bevacizumab/administration & dosage , Ranibizumab/administration & dosage , Time Factors , Reproducibility of Results , Retrospective Studies , Analysis of Variance , Treatment Outcome , Angiogenesis Inhibitors/administration & dosage , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Tomography, Optical Coherence , Intravitreal Injections/methods , Bevacizumab/adverse effects , Ranibizumab/adverse effects
15.
Arq. bras. oftalmol ; 77(4): 214-218, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-728665

ABSTRACT

Purposes: To validate a teleophthalmology mobile system aimed at improving and providing eye urgency screenings in remote and poor area settings in Brazil. The system enables one or more ophthalmologists to remotely examine a patient's condition and submit a decision describing the gravity of the case. If necessary, the patient can be forwarded to a hospital for further consultation. Methods: A cellphone (Nexus One model, with a 5 megapixel camera) was used to collect data and pictures from 100 randomly selected patients at the Ophthalmology Emergency Room located at the General Hospital of the Federal University of São Paulo (UNIFESP). Data was then sent remotely to an online recording system to be reviewed by an ophthalmologist who provided feedback regarding the state of ocular urgency. Results were then compared to the gold standard diagnosis provided at the hospital. Results: The diagnosis of urgency was given by two ophthalmologists: one in the hospital (gold standard) and one remotely. When we compared both diagnoses we obtained results of 81.94% specificity, 92.85% sensitivity, and 85% accuracy, with a negative predictive value of 96.72%. This work also included a processing time analysis, resulting in an average time of 8.6 min per patient for remote consultations. Conclusions: This study is the first that has used only a cellphone for diagnosing the urgency of ocular cases. Based on our results, the system can provide a reliable distinction between urgent and non-urgent situations and can offer a viable alternative for the servicing of underprivileged areas. In screening techniques, the most important outcome is to identify urgent cases with a high level of sensitivity and predictive negative value. Thus, our results demonstrate that this tool is robust and we suggest that a major study aimed to verify its efficiency in resource-poor areas should be initiated. .


Objetivos: Validar um sistema de teleoftalmologia móvel que tem como objetivo fornecer triagem de urgências oftalmológicas em áreas remotas e desfavorecidas do Brasil. O sistema permite que um ou mais oftalmologistas possam examinar remotamente a condição do paciente e apresentar uma decisão que descreve a gravidade do caso. Se necessário, o paciente será encaminhado ao hospital para consulta. Métodos: Através de um celular e sua câmera (modelo Nexus One com câmera de 5 megapixel), foram coletados dados de 100 pacientes aleatoriamente selecionados no pronto socorro oftalmológico da Universidade Federal de São Paulo (UNIFESP) e enviados remotamente para um sistema online, por meio do qual um oftalmologista analisou-os e enviou um diagnóstico sobre a gravidade dos casos. Os resultados enviados foram comparados com o padrão ouro que foi fornecido pelo médico no hospital. Resultados: O diagnóstico foi fornecido por dois oftalmologistas: um no hospital (padrão outro) e outro remotamente. Comparando os resultados dos diagnósticos, foi obtido 81,94% de especificidade, 92,85% de sensibilidade, acurácia de 85% e um valor preditivo negativo de 96,72%. Também foi testado o desempenho do sistema, resultando num tempo de processamento do atendimento remoto em média de 8,6 minutos por paciente. Conclusões: Esta solução de baixo custo é a primeira da literatura que utiliza apenas o telefone celular para detectar urgências oftalmológicas. Com base nos resultados, o sistema consegue oferecer um atendimento confiável, diferenciando os casos de urgências e não urgências através da plataforma de telemedicina. Como ferramenta de triagem, o mais importante é identificar os casos de urgência (ter alta sensibilidade). Assim, os resultados obtidos demonstram que a ferramenta ...


Subject(s)
Humans , Cell Phone , Eye Diseases/diagnosis , Telemedicine/methods , Brazil , Computer Communication Networks , Predictive Value of Tests , Remote Consultation/methods , Sensitivity and Specificity , Surveys and Questionnaires
16.
Arq. bras. oftalmol ; 74(3): 214-216, May-June 2011. ilus
Article in Portuguese | LILACS | ID: lil-598319

ABSTRACT

Descrevemos o caso de uma paciente, de 53 anos, com quadro de oclusão de ramo venoso da retina após receber seis infusões de infliximabe (3 mg/kg/dose), para tratamento de artrite reumatóide. A investigação clínica e laboratorial sobre distúrbios de coagulação, cardiopatias e sinais de hipertensão arterial crônica foi negativa. A relação temporal do uso de infliximabe e o desenvolvimento do quadro de oclusão de ramo pode indicar um possível efeito adverso da medicação.


A case of a 53 year-old female patient who developed branch retinal vein occlusion after six 3 mg/kg Infliximab infusions for rheumatoid arthritis treatment is reported. Hematological disorders, cardiopathy and chronic systemic hypertension evaluation were negative. The relationship between the infliximab therapy and the development of retinal vein occlusion raises awareness of the possibility of a potential side effect of this medication.


Subject(s)
Female , Humans , Middle Aged , Antibodies, Monoclonal/adverse effects , Antirheumatic Agents/adverse effects , Retinal Vein Occlusion/chemically induced , Fluorescein Angiography , Visual Acuity
17.
Arq. bras. oftalmol ; 73(6): 505-507, nov.-dez. 2010. tab
Article in English | LILACS | ID: lil-572213

ABSTRACT

Purpose: To report on the incidence, diagnostic technique, and microbiological features of endophthalmitis at a university-setting in Brazil. Methods: All cases of presumed postoperative endophthalmitis from 2002 to 2008 at a teaching-hospital were included. Main data assessed were: number of cataract surgeries performed, incidence of endophthalmitis, microbiological outcome (aqueous and/or vitreous culture and Gram staining), and antimicrobial susceptibility testing of the positive cases. Results: Seventy-three eyes of 73 patients (43 females and 30 males) developed endophthalmitis after 24,590 cataract surgeries. The incidence decreased from 0.49 percent in 2003 to 0.17 percent in 2006 and stabilized afterwards. Coagulase negative Staphylococci (CoNS) and Streptococcus viridans (56.5 percent and 15 percent, respectively) were the most common bacterial isolates. Culture and Gram stain were negative in 36.9 percent. CoNS presented susceptibility rates of 80 percent-sensitivity to oxacillin, 90 percent to fourth-generation quinolones and 100 percent to vancomycin. Conclusions: The rate of endophthalmitis, diagnostic ability of conventional laboratory investigation, microbial isolates and antibiotic susceptibility are in accordance with other findings of the literature. Despite using prophylactic antibiotic drops, it was possible to identify cases that were susceptible to the antibiotics topically applied.


Objetivo: Relatar incidência, técnica diagnóstica e características microbiológicas de endoftalmite numa instituição universitária no Brasil. Métodos: Todos os casos de endoftalmite pós-operatória presumida de 2002 a 2008 foram incluídos. Os principais dados avaliados foram: número de cirurgias de catarata realizadas, incidência de endoftalmite, resultado microbiológico (bacterioscopia e cultura de aquoso e vítreo) e teste de sensibilidade antibiótica dos casos positivos. Resultados: Setenta e três olhos de 73 pacientes (43 do sexo feminino e 30 do masculino) desenvolveram endoftalmite após 24.590 cirurgias de catarata. A incidência reduziu de 0,49 por cento em 2003 para 0,17 por cento em 2006 e estabilizou-se depois disso. Staphylococcus coagulase-negativa (SCoN) e Streptococcus viridans (56.5 por cento e 15 por cento, respectivamente) foram os isolados bacterianos mais comuns. Cultura e bacterioscopia foram negativas em 36,9 por cento. SCoN apresentou taxas de sensibilidade de 80 por cento à oxacilina, 90 por cento às quinolonas de quarta geração e 100 por cento à vancomicina. Conclusões: A taxa de endoftalmite, a capacidade diagnóstica das técnicas laboratoriais convencionais, os microrganismos isolados e a sensibilidade aos antibióticos estão em acordo com outros achados na literatura. Apesar do uso profilático de colírio antibiótico, foi possível identificar casos de infecção em que as bactérias eram sensíveis aos antibióticos usados topicamente.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cataract Extraction/adverse effects , Endophthalmitis/epidemiology , Bacteria/isolation & purification , Brazil/epidemiology , Endophthalmitis/microbiology , Hospitals, University , Incidence , Microbial Sensitivity Tests , Treatment Outcome
18.
An. acad. bras. ciênc ; 81(3): 409-429, Sept. 2009. ilus, tab
Article in English | LILACS | ID: lil-523987

ABSTRACT

Heparan sulfate proteoglycans are ubiquitously found at the cell surface and extracellular matrix in all the animal species. This review will focus on the structural characteristics of the heparan sulfate proteoglycans related to protein interactions leading to cell signaling. The heparan sulfate chains due to their vast structural diversity are able to bind and interact with a wide variety of proteins, such as growth factors, chemokines, morphogens, extracellular matrix components, enzymes, among others. There is a specificity directing the interactions of heparan sulfates and target proteins, regarding both the fine structure of the polysaccharide chain as well precise protein motifs. Heparan sulfates play a role in cellular signaling either as receptor or co-receptor for different ligands, and the activation of downstream pathways is related to phosphorylation of different cytosolic proteins either directly or involving cytoskeleton interactions leading to gene regulation. The role of the heparan sulfate proteoglycans in cellular signaling and endocytic uptake pathways is also discussed.


Proteoglicanos de heparam sulfato são encontrados tanto superfície celular quanto na matriz extracelular em todas as espécies animais. Esta revisão tem enfoque nas características estruturais dos proteoglicanos de heparam sulfato e nas interações destes proteoglicanos com proteínas que levam à sinalização celular. As cadeias de heparam sulfato, devido a sua variedade estrutural, são capazes de se ligar e interagir com ampla gama de proteínas, como fatores de crescimento, quimiocinas, morfógenos, componentes da matriz extracelular, enzimas, entreoutros. Existe uma especificidade estrutural que direciona as interações dos heparam sulfatos e proteínas alvo. Esta especificidade está relacionada com a estrutura da cadeia do polissacarídeo e os motivos conservados da cadeia polipeptídica das proteínas envolvidas nesta interação. Os heparam sulfatos possuem papel na sinalização celular como receptores ou coreceptores para diferentes ligantes. Esta ligação dispara vias de sinalização celular levam à fosforilação de diversas proteínas citosólicas ou com ou sem interações diretas com o citoesqueleto, culminando na regulação gênica. O papel dos proteoglicanos de heparam sulfato na sinalização celular e vias de captação endocítica também são discutidas nesta revisão.


Subject(s)
Humans , Endocytosis/physiology , Extracellular Matrix Proteins/physiology , Heparan Sulfate Proteoglycans/physiology , Signal Transduction/physiology , Cell Adhesion/physiology , Heparan Sulfate Proteoglycans/chemistry , Protein Binding/physiology
19.
Arq. bras. oftalmol ; 71(5): 623-628, set.-out. 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-497210

ABSTRACT

PURPOSE: To evaluate the inflammatory response associated with the use of processed porcine pericardium and glycerin-preserved homologous sclera as silicone glaucoma drainage device coverage in a rabbit experimental model. METHODS: Eight New Zealand white rabbits' eyes received an equal-sized glycerin-preserved homologous scleral patch or a double-layered processed porcine pericardium that was sutured to the bare sclera covering a silicone tube. Conjunctival hyperemia was graded using the double-blind method during the immediate postoperative period and during the first, third, and seventh postoperative weeks. After the seventh week, the enucleated eyes were histopathologically examined. They were also evaluated for signs of patch graft melting, tube erosion and chemosis. RESULTS: There was no occurrence of graft melting or tube exposure, although porcine pericardium was associated with greater inflammation through clinical observation. Light microscopy revealed marked inflammation surrounding the porcine pericardium with foreign body granuloma formation. On the other hand, the sclera group presented milder inflammation with foreign body granulomas only around the sutures. CONCLUSIONS: Porcine pericardium is associated with significant inflammation when used as tube coverage in a rabbit model, at both histopathologic and clinical levels, when compared to glycerin-preserved homologous sclera during the seven-week follow-up period.


OBJETIVO: Avaliar a resposta inflamatória associada com o uso de pericárdio suíno processado e esclera homóloga preservada em glicerina no recobrimento de tubo de drenagem de silicone utilizado em cirurgia de glaucoma em modelo experimental. MÉTODOS: Oito olhos de 8 coelhos albinos da raça Nova Zelândia receberam enxertos do mesmo tamanho de esclera homóloga, preservada em glicerina ou pericárdio suíno processado, suturados à esclera recobrindo um tubo de silicone. Os olhos foram avaliados quanto à hiperemia conjuntival de modo mascarado na primeira, terceira e sétima semanas de pós-operatório. Após a sétima semana os olhos foram enucleados e submetidos a estudo histopatológico. Os olhos também foram avaliados quanto à presença de afinamento do enxerto, exposição do tubo e quemose. RESULTADOS: Não ocorreram casos de afinamento do enxerto ou exposição do tubo, porém o pericárdio suíno esteve associado clinicamente a uma maior inflamação. Achados à microscopia óptica incluíram intensa reação inflamatória em torno do enxerto de pericárdio com formação de granuloma do tipo corpo estranho. Por outro lado, no grupo que recebeu esclera, ocorreu formação de granulomas apenas em torno dos fios de sutura. CONCLUSÃO: O pericárdio suíno esteve associado a maior inflamação tanto à histopatologia quanto clinicamente, quando usado no recobrimento de tubo de silicone, em comparação à esclera homóloga preservada em glicerina, durante o período de acompanhamento de sete semanas.


Subject(s)
Animals , Rabbits , Glaucoma Drainage Implants , Glaucoma/surgery , Pericardium/transplantation , Sclera/transplantation , Foreign-Body Reaction/pathology , Hyperemia/pathology , Pericardium/pathology , Swine , Sclera/pathology , Time Factors
20.
Arq. bras. oftalmol ; 71(2): 149-152, mar.-abr. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-483018

ABSTRACT

OBJETIVO: Avaliar a epidemiologia do trauma ocular por corpo estranho superficial de córnea. MÉTODOS: Os pacientes atendidos no Pronto-Socorro da Universidade Federal de São Paulo entre abril e junho de 2005 que apresentaram corpo estranho superficial de córnea foram entrevistados. Foram avaliados: sexo, idade, profissão, registro legal do emprego, uso, disponibilidade e tipo de equipamentos de proteção utilizados e a fiscalização do seu uso. O conhecimento das complicações deste tipo de acidente também foi avaliado. Os resultados foram analisados com teste do qui quadrado ou teste de Fisher. RESULTADOS: Foram entrevistados 123 pacientes. Apenas 3 eram do sexo feminino e a idade média foi de 36 anos. A maioria destes traumas ocorreu no ambiente de trabalho (86,2 por cento) e 58,4 por cento não possuíam registro legal do emprego. As profissões mais freqüentemente envolvidas foram serralheiro, pedreiro e metalúrgico. Em 79,8 por cento dos locais de trabalho havia equipamentos de proteção e 85,3 por cento dos pacientes eram orientados a usá-los. Em 52,4 por cento dos locais sua utilização era fiscalizada, mas apenas 34,2 por cento usavam no momento do trauma. A utilização foi mais freqüente (p=0,008) e fiscalização mais presente (p=0,0415) entre pacientes com registro legal de emprego. Questionados sobre os riscos, 68,9 por cento dos pacientes tinham consciência das complicações graves deste tipo de acidente. CONCLUSÃO: A maioria dos pacientes tem conhecimento sobre a gravidade do trauma ocular e este tipo de lesão ocorre mesmo em locais com equipamentos de proteção disponíveis, alguns deles até durante o seu uso. Os dados sugerem que enfoque maior da prevenção deve ser na fiscalização e utilização de equipamentos adequados.


PURPOSE: To evaluate the epidemiology of superficial corneal foreign body. METHODS: Patients who were seen at the Emergency Service of the Federal University of São Paulo, from April/05 to June/05, were screened and those with superficial corneal foreign body were interviewed. Data regarding gender, age, occupation, employment status, availability and use of protective devices and supervision of their use were collected. Awareness of the possible complications was also assessed. Results were analyzed using chi-square or Fisher exact test. RESULTS: One hundred twenty-three patients were interviewed. Only 3 patients were female. The mean age was 36 years. Most injuries occurred at the workplace (86.2 percent), and 58.4 percent of the patients did not have a legal employment registration. The occupational activities most frequently reported were construction related activities (44.3 percent) and welding/soldering (11.3 percent). In most workplaces (79.8 percent) protective devices were available and 85.3 percent of the patients were instructed to use them. A safety device was being used during the accident in 34.2 percent of the cases and this was more frequent among patients that had legal employment registry (p=0.008) and among those under supervision (p=0.0415). The majority of the patients (68.9 percent) were aware of the risk of severe complications. CONCLUSIONS: Most patients with superficial corneal foreign body are aware of its severe complications and injuries usually occur in places where safety devices are available and often during their use. Our findings suggest that prevention should focus on supervision and correct use of safety devices.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Accidents, Occupational/statistics & numerical data , Eye Foreign Bodies/epidemiology , Occupations , Welding , Awareness , Accidents, Occupational/prevention & control , Brazil/epidemiology , Chi-Square Distribution , Construction Materials/adverse effects , Employment , Eye Foreign Bodies/complications , Eye Foreign Bodies/prevention & control , Eye Protective Devices , Health Knowledge, Attitudes, Practice , Registries , Workplace
SELECTION OF CITATIONS
SEARCH DETAIL